Switching over fine
This is what a reversing valve doing its job looks like from outside. Flip the thermostat to cool and the unit answers, the coil stays clear, and the air coming out of your vents actually feels cold within a few minutes.
A heat pump stuck in heat mode usually means the reversing valve is not switching. That valve is what lets the system flip between heating and cooling, and it's controlled by a small solenoid that can stick or fail outright. Sometimes it's not the valve itself but the thermostat or a control board signal not telling it to switch. In Tennessee this often shows up in spring, when the first warm days push you to switch over and the system just keeps putting out heat. Since most homes here heat with electricity through the same heat pump that cools the house, a stuck reversing valve leaves you without air conditioning too, not just stuck with warm air you don't want. It won't fix itself by adjusting the thermostat. The valve or the part telling it what to do needs to be looked at directly.

The reversing valve has a solenoid coil mounted on top. When your thermostat calls for cooling, that coil gets energized and slides a pin inside the valve, redirecting refrigerant flow. If the coil burns out or the pin corrodes in place, the valve stays wherever it last sat. Since most Tennessee heat pumps sit in heat mode most of the year, a stuck valve almost always fails toward heat. A contractor can test the coil with a multimeter in minutes.

A heat pump that won't switch can sit fine all winter and only reveal the problem the first warm day you need cooling. Tennessee summers get sticky fast, so a system blowing warm air in June gets noticed quickly. The valve itself can be fine while the fault is a bad connection at the solenoid or a control board that never sends the signal. Either way, the symptom looks the same from the thermostat.
Set the thermostat to cool and warm air still comes out of the vents. The outdoor unit runs, you can hear the fan, but nothing inside feels like cooling. Some homeowners notice the outdoor coil icing up even though it's eighty degrees outside. Others just notice the house won't drop below where it already sits no matter how low they set it. Since most homes here heat with electricity, this same system is what keeps the house warm come winter, so a reversing valve that's stuck or failing now is worth sorting before cold weather asks it to switch the other way. Left alone through a sticky Tennessee summer, the outdoor unit can run long hours for no cooling at all.

This is what a reversing valve doing its job looks like from outside. Flip the thermostat to cool and the unit answers, the coil stays clear, and the air coming out of your vents actually feels cold within a few minutes.

Same kind of unit, same spot by the wall, but the valve inside won't move. The outdoor fan runs, the compressor comes on, and warm air keeps coming out of the vents no matter where you set the thermostat.




Nobody opens up a reversing valve to fix it. It's a sealed unit, so when it's actually bad, the whole thing gets swapped, not repaired. That's why the first step isn't touching the valve at all. A tech puts a meter on the solenoid coil and checks for 24 volts, because that tells him whether the thermostat signal is reaching the valve in the first place. Voltage there but no shift usually means the coil burned out, which is a smaller job than replacing the full valve. No voltage, or a valve that's mechanically stuck, sometimes responds to a sharp tap on the body while the system runs, enough to free a corroded pin. Low refrigerant can cause the exact same symptom without the valve being at fault, since the valve needs a certain pressure difference to slide. If it really is the valve, the job means recovering the refrigerant, brazing the new valve in place, pulling a vacuum, and recharging the system back to its original weight.



Only one pro gets your request, so you hear from one company.
Send it once and finding someone is no longer on you.
You're not committing to anything by asking.

NOAA puts the summer dew point across Tennessee at 66°F on average for June, July and August. That's heavy air, the kind that makes cooling do real work. A heat pump stuck in heat mode gives you none of that relief. Warm air blows while the moisture outside stays put, and the air inside your house starts feeling just as sticky as the air outside it. A system that switches over fine would be pulling that moisture out along with the heat. Stuck the way it is, it can't, and you'll notice it on your skin before you notice it on the thermostat.
NASA POWER T2MDEW county cells weighted by homes
Some homeowners figure if the reversing valve is just stuck, maybe a few taps with a wrench or a jolt from the breaker will knock it loose, the way you'd jiggle a sticky light switch. It's a reasonable thing to try before paying anyone. The valve looks simple enough from outside the cabinet, just a block with copper lines running into it, so it seems like it should respond to a little persuasion.
The solenoid needs 24 volts from the thermostat to move the pin, and if that signal isn't reaching it, tapping on the valve won't substitute for the electrical current. If the pin is corroded or the coil has burned out, the valve is sealed shut and no amount of force from outside the cabinet reaches the part that's actually stuck. Worse, the valve body is thin copper holding refrigerant under pressure. Hit it wrong and you crack the line instead of freeing the pin, and now you've turned a stuck valve into a refrigerant leak. A tech checks for voltage at the coil first, because that tells whether the problem is electrical or mechanical before anything gets touched.
Thermostat sends a 24 volt signal to the reversing valve solenoid
Solenoid coil energizes and should pull the valve's internal pin
Pin fails to move, so refrigerant keeps flowing in the heating path
Outdoor coil stays in heating mode while indoor air blows warm


At 13.22 cents a kilowatt-hour, running a heat pump that's stuck heating instead of cooling costs you twice. You're paying to heat a house that needs cooling, then paying again once it's fixed and actually has to catch up on a hot day.
EIA-861 2025 statewide residential average
A small plumbing problem gets fixed before it floods the basement. A stuck reversing valve deserves the same treatment, because it's a cheap part sitting inside an expensive system.
Left alone, the valve doesn't improve on its own, and the compressor keeps running against a system that's heating when it should be cooling.


A heat pump stuck in heat mode almost always comes back to the reversing valve, and that's a known part with a known fix. The solenoid either gets 24 volts and moves the pin or it doesn't, and a tech can tell which within minutes of looking. From there it's a matter of swapping the valve as a sealed unit, not rebuilding anything in your attic or your side yard.
What matters now is who handles it. Someone who works on heat pumps all through a Tennessee summer has seen this exact failure enough times to know where to look first. That's not guesswork on your system, it's a repair they've done before on units like yours, in heat like this. You get one licensed contractor assigned to the job, not a handful of companies competing for your number and calling within the hour of each other. That means one visit to schedule, one person who already knows what's wrong before they knock on your door, and no sorting through competing quotes while your house sits warm.
The part itself isn't the expensive piece here. Letting it run stuck is what costs you, since the system keeps drawing power to heat a house that needs cooling. Once the valve switches the way it's built to, the compressor stops working against itself and the air coming out of your vents actually matches what the thermostat says. You caught this while it was still a part swap instead of a compressor replacement, and that's the right order to do things in.